GALAN - electric caldrons and heating equipments,  GALAN - for houses, apartments, offices and 
cottages
Latvia; Riga; SIA "ALOVS"; Codes str. 24, LV-1003; tel/fax (+371) 67610688, mobile: 26761172
e-mail: galan@alovs.lv
Energo saving instruments of the new generation and economical systems of the heating
Models charts of connecting of electric caldrons
Of principle chart of connecting electric
caldron ""
1. Electro-caldron

2. Three moves valve
3. Pump of circulation
4. Filter
5. Drain valve
6. Dilator tank
7. Automation
8. Air to withdrew
Chart of the parallel connecting electric
caldron ""
1. Electro-caldron

2. Three moves valve
3. Pump of circulation
4. Filter
5. Drain valve
6. Dilator tank
7. Automation
8. Air to withdrew
9. Other source of heat (gas, oily or caldron on a
hard fuel)
Connecting chart electric caldron "" to the chimney
1. Electro-caldron

2. Three moves valve
3. Pump of circulation
4. Filter
5. Drain valve
6. Dilator tank
7. Automation
8. Air to withdrew
Connecting chart electric caldron "|" to
the radiator + warming up of floor
 
Attention!
The area of warm floor not must exceed 30% to
all heated area.
 
1. Electro-caldron
2. Ball's valve
3. Pump of circulation
4. Filter
5. Drain valve
6. Dilator tank
7. Automation
8. Air to withdrew
9. Other source of heat (gas, oily or caldron on a
hard fuel)
10. Three moves valve
11. Contour of heating of floor
12. Automation of heating of floor
Connecting chart electro- caldron  "" to heating of
floor
1. Electro-caldron

2. Ball's valve
3. Pump of circulation
4. Filter
5. Drain valve
6. Dilator tank
7. Automation
8. Air to withdrew 
9. Other source of heat (gas, oily or caldron on a hard fuel)
10. Three moves valve
11. Contour of heating of floor
12. Automation of heating of floor
13. Room thermostat
14. Motor of contour
15. Baypas
For the start of electrode caldron in the system working on the warm floor it is necessary to prepare water  as
follows:
- To start the system and measure a current at the temperature of backpipe with 40 C.
Caldron
 Maximal current at
40 C
 2 kW
 10 A
 3 kW
 13 A
 5 kW
 25 A
 6 kW
 28 A
 9 kW
 220 V - 40 A
380 V - 16 A
 15 kW
 25 A
 25 kW
 40 A
 
If at 40 degrees on a backpipe | current falls short of to the parameters indicated in a table, it is necessary to
make the followings actions:
 
1.    A current is less than - it is necessary to add salt contains | solution stage-by-stage (it diminishes specific resistance to the
liquid). First stage - no more tea-spoon salt waters on one hundred litres. If in 4 hours a current was multiplied it is
insignificantly necessary to repeat the first stage.
2.    A current is anymore - add the distilled water (it multiplies specific resistance to the liquid).
After preparation of water temperature on an exit from a caldron (sensor 2) to decrease to 40 degrees.
Attention!
At the use of electrodes caldrons for heating of chaffs the expense of electric power is considerably
multiplied.